Emission Monitoring and Gas Analysis

Our Products: Dust Collector Parts/Components > Goyen Parts > Emission Monitoring and Gas Analysis
Emission Monitoring and Gas Analysis
Tyco Environmental Systems (TES) - offers a complete range of Continous Emission Monitoring, Particulate Opacity Monitoring, Combustion Control, Process Analysis and Control, Cross Stack Gas Analysis and Portable Gas Equipment that can be utilised across a multitude of industrial applications. With thousands of successful installations worldwide, TES understands the specific requirements of industry, and can tailor an effective solution for even the most challenging application. TES' continous monitoring systems take the guess work out of environmental management, providing accurate data for reporting purposes and minimising the risk of costly environmental licensing infringements. Gas and particulate monitors also double as preventative maintenance tools, determining optimum efficiency levels in combustion processes and maximising the life of baghouse filters.
Specify a quantity for any of the products listed on this page, then click 'Add to Cart' to add them to your shopping cart. If the quantity field is not visible for a product, you must click on the 'More Details' button and select the options or fill out the fields that require your input.
Qty   SKU Description Price

BBD6 Broken Bag Detector

BBD6-4100
The BBD6 utilises AC Coupled Triboelectric technology. As particles travel through the process they develop a charge. This charge is transferred as the particle passes or impacts the sensing element. The resulting current is amplified, filtered, rectified and further filtered looking only at the AC component, giving a linear representation of the concentration or mass flow rate of the particles in the gas stream. The reason for measuring the AC component is that, compared to the DC component, the electronics are more sensitive. The AC signal is substantially less affected by influences such as amplifier noise and process parameters, which includes the build-up of process dust on the sensing rod. The BBD6 remote sensing head totally filters out any 50 Hz or 60 Hz frequencies related to mains supply. The amplified signal is then sent via data cable to the control unit for further processing and display.
CAD$1,312.20
You Save: CAD$109.36 (8%)

EMP6 Particulate Emission Monitor

EMP6-3100
The EMP6 utilises AC Coupled Triboelectric technology. As particles travel through the process they develop a charge. This charge is transferred as the particle passes or impacts the sensing element. The resulting current is amplified, filtered, rectified and further filtered looking only at the AC component, giving a linear representation of the concentration or mass flow rate of the particles in the gas stream. The reason for measuring the AC component is that, compared to the DC component, the electronics are more sensitive. The AC signal is substantially less affected by influences such as amplifier noise and process parameters, which includes the build-up of process dust on the sensing rod. The EMP6 remote sensing head totally filters out any 50 Hz or 60 Hz frequencies related to mains supply. The amplified signal is then sent via data cable to the control unit for further processing and display.
CAD$1,712.71
You Save: CAD$142.73 (8%)

EMS6 Particulate Emission Monitor

EMS6-3200
The EMS6 utilises AC Coupled Triboelectric technology. As particles travel through the process they develop a charge. This charge is transferred as the particle passes or impacts the sensing element. The resulting current is amplified, filtered, rectified and further filtered looking only at the AC component. This gives a linear representation of the concentration or mass flow rate of the particles in the gas stream, depending on the chosen scale of calibration. The reason for measuring the AC component is that, compared to the DC component, the electronics are more sensitive. The AC signal is substantially less affected by influences such as amplifier noise and process parameters, which includes the build-up of process dust on the sensing rod. The EMS6 totally filters out any 50 Hz or 60 Hz frequencies related to mains supply. The digital signal is then sent via a data cable to PLC, SCADA or a Connect Network System. The EMS6 linear representation of concentration or mass flow has been validated by independant laboratories. The EMS6 along with ANJ1, ANP1 and Connect software has been tested and certified for monitoring dust emissions according to the "MCERTS" standard.
CAD$2,588.22
You Save: CAD$214.69 (8%)

EMP7 Particulate Emission Monitor

EMP7-3200-CSA
The EMP7 utilises ISE technology. Each particle travelling through the process develops an electrical charge. As the particle passes or impacts with the sensing element, a current is induced which is processed in EMP7 by a method called Impulse Signature Extraction ("ISE"). ISE technology extracts the basic characteristics (the "signature") of the impulsive signals induced by individual particles in the gas stream. Since these characteristics are related to such things as the particle velocity, EMP7 is able to compute velocity as a parameter, and therefore to calculate the emission level as either mass flow rate or mass density as required. In addition, although ISE technology processes the entire signal from the sensing element, its algorithm effectively negates the potentially erroneous effects of the DC component of the signal, so ISE technology shares all the advantages of existing AC Triboelectric technology. Made a reality by recent advances in low power digital signal processing, ISE technology is as significant a step forward now as the introduction of AC Triboelectric technology was in 1992.
CAD$1,957.44
You Save: CAD$163.12 (8%)